                                                | Modbus RTU,
                                                    Modbus TCP, cascade, multi-master monitoring |  
                                                | Background |  
                                                | Modbus is the
                                                    world's first bus protocol to be truly used in industrial fields,
                                                    published by Modicon (a brand of Schneider Electric) in 1979. Till
                                                    now Modbus enables thousands of devices to communicate. Internet
                                                    organizations enable the reserved system port 502 on the TCP / IP
                                                    line access Modbus.
                                                    Modbus protocol supports traditional serials RS-232, RS-485 and
                                                    Ethernet devices. Many industrial devices, including PLCs, DCSs and
                                                    smart meters, are using Modbus protocol as a communication standard
                                                    between them. |  
                                                | Case Study |  
                                                | In this
                                                    application, SST MT-RS series gateways have dual Ethernet interface,
                                                    built-in switch, support cascade, can be used in looped network;
                                                    field connection can save cable and switch. Network security part:
                                                    can limit communication client's IP address range and set the login
                                                    password to protect the network security. Communication part: can
                                                    support 4 Modbus TCP masters to communicate at the same time, and
                                                    can support 32 command requests at the same time. |  | 
                                            